Key Words: Impluse tester, Hipot Tester, Megger, Load bank

USA Tel:(816) 666-7843

E-Nanny Electric Automation Co., Ltd.

DBJS-6 Hipot Tester for Insulating Gloves/Boots/Rods

DBJS-6 Hipot Tester for Insulating Gloves/Boots/Rods is a special equipment for batch test of insulated gloves, boots and rods.

Download

Description

Product Introduction

DBJS-6 Hipot Tester for Insulating Gloves/Boots/Rods is a special equipment for batch test of insulated gloves, boots and rods, which simply test procedure, improve test speed and reduce test strength. This guarantee test persons' security and identify parameters of leakage current, insulation aging and frequency voltage reliably. It can test 6pcs insulated glove(boot) at the same time.

The device integrates high voltage power with control system. It includes the following characteristics: easy wiring and testing, reliable and reasonable layout, convenient moving, flexible dismounting, which is ideal product for updated generation.

 

Product Features

Manual control unit

l  Digital and real time display HV voltage, LV current, 6-way leak current

l  and time.

l  With leak current meter and over-current protection meter.

l  With movable control unit, easy wiring and testing.

l  Manual control, safety and reliability.

l  With zero, power, operation, timing indicators.

l  With over-current protection, zero-start protection, sound and light alarm, power protected switch.

l  New type timer, broader timing range. (1s-99h)

Other Features

l  HV source is oil immersed type testing transformer. It is suitable for testing insulation gloves(boots), 6-110kV insulation rod.

l  To make test for insulation gloves and boots, the HV electrode is chain type, which the height can be adjusted. The material is stainless steel with CU / EpNi5bc painted, which make surface discharge< 10pc. 6pcs insulation barrels are also supplied.

l  With insulation rod stand to make withstand voltage and leak test for insulation rod.

l  With electrode for withstand voltage and leak test of insulation mat and blanket.

l  Control unit and HV unit are separate, to ensure safety.

l  If there is breakdown or over limits, the HV output will be cut off automatically and alarm.

 

Technical Specifications

• Rated capacity: 3kVA

• Input voltage: AC220V±10% 50Hz±1

• Output voltage: 0-100kV

• Voltage accuracy: ≤2.0% (F.S)

• Low voltage current: 0-15A

• Leakage current: 0-20.0mA

• Leakage current resolution: 0.1mA

• Current accuracy: ≤1.5% (F.S)

• Timing range: 0-999s

• Environmental temperature: -20 to 50


Inquiry