E-Nanny Electric Automation Co., Ltd.

DBM2671 Insulation Resistance Tester

This style of digital multimeter is designed and manufactured according to the safety requirements set out by the IEC61010-1 standards for electronic test instruments . Its design and manufacture is strictly based on the provisions in the 1000V CAT Ⅲ of IEC61010-1 and the Stipulation of 2-Pollution Grade.


Download

Description

 Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired.

 Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. If in doubt, have the Meter serviced.

 Always use the proper terminal, switch position, and range for measurements before connecting Meter to circuit under test.

 Verify the Meter’s operation by measuring a known voltage.

 Do not apply more than the rated voltage as marked on the Meter, between the terminals or between any terminal and earth ground.

 Use caution with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. These voltages pose a shock hazard.

 Replace the battery as soon as the low battery indicator ( ) appears.

 Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.

 Do not use the Meter around explosive gas or vapor.

 When using the test leads, keep your fingers behind the finger guards.

 Remove test leads from the Meter before opening the Meter case or battery door.

 Never operate the Meter with the cover removed or the battery door open.

 Comply with local and national safety requirements when working in hazardous locations.

 Use proper protective equipment, as required by local or national authorities when working in hazardous areas.

 Use only the replacement fuse specified or the protection may be impaired.


Specifications

 Complies with IEC/EN 61010-1 1000V CAT III 600 V CAT IV.

 1000V DC Voltage,750V AC Voltage.

 when the input terminals is Hi and Lo , The overload protective voltage is 600V. When the input terminals is V and COM, the overload protective voltage is 1200 V under the voltage test; in other test mode ,the overload protective voltage is 250V.

 Batteries:six AA batteries (NEDA 15A or IEC LR6) Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.

 Insulation Measurement Range : 0.01 MΩ to 100.0 GΩ.

 Insulation Test Voltages : 50V, 100V,250V, 500V, 1000 V .

 Insulation Source Voltage: + 20 %, - 0 %.

 Insulation Short-Circuit Test Current : 1.8mA nominal.

 insulation test automatic discharge time : Capacitance (C) = 1 μ F or less, discharge time < 1 second

 Insulation Live Circuit Detection : Inhibit test if terminal voltage > 20 V prior to initialization of test.

 Insulation Maximum Capacitive Load: Operable with up to 1 μ F load.

 Storage Temperature : -40 °C to 60 °C.

 Operating Temperature: 0°C to 40 °C .

 Storage Altitude: 12000m

 Operating Altitude: 2000m 1000V CAT III,3000m 1000V  Ⅱ

 Temperature Coefficient: 0.05 × (specified accuracy) per °C for temperatures < 18 °C or > 28 °C.

 Relative Humidity: 40%~75%(40%~60% when insulation test >1 GΩ )

 Size: 180(L) mm×140(W) mm× 65(H)mm.

 Weight: approx 900g.(not including battery)